Personal CO/ O2 Monitor

XOC-2200

Application

For safety check and safety in plants, tank, manhole, and tunnel construction

Specifications

Model XOC-2200
Gas Detected Oxygen (O2) Carbon Monoxide (CO)
Detection Principle Galvanic cell Electrochemical cell
Sampling Method Diffusion
Detection Range (Service Range) 0 to 25 vol% (25-50vol%) 0 to 300 ppm
Resolution 0.1vol% 0-300ppm: 1ppm 301-2,000ppm: 50ppm
Indication Accuracy*1 Within ±0.5vol% Within±30ppm
Alarm Set Value 1st stage: 19.5vol% 2nd stage: 18.0vol% 1st stage: 50ppm, 2nd stage: 150ppm, 150ppm ・ h (time weighted average)
Response Time*2 20s or less 30s or less
Display Mode LCD (Manual backlight)
Alarm Mode Buzzer sounds, flashing red light, vibrator
Approvals Ex ib IIB T3 (TIIS)
Function Remaining battery level, peak hold, peak value memory, readout of time weighted average, remainig battery level, alarm functions except gas alarm (time weighted average, sensor malfunction, battery level, zero-adjustment malfunction), gas calibration, gas concentration indication
Operation Temperature -10°C to +40°C, 30 to 90 %RH (non-condensing)
Operation Air Pressure Air pressure ±10%
Power Source 1 x AAA alkaline dry cell
Battery Life*3 Up to 5,000 hours (at 20°C with less than 20ppm of CO and more than 20.3vol% of O2)
Dimensions W65 x H64 x D22mm (excluding protrusions)
Weight Approx. 75g (including batteries)
Standard Accessories 1 x AAA alkaline dry cell, 1 x safety pin adaptor (with fixing screw)

Approvals

ATEX_logo CE_logo

Selectable Gases

oxygen【O2】, carbon monoxide【CO】