COMBUSTIBLE GAS DETECTORS
Combustible gas detectors are used in work places that use combustible gas in order to secure worker safety, detect the location of any leakage, and measure gas concentrations.
Multi Gas Detector
XP-3368II-W / XP-3368II / XP-3318II
Application
For daily check and safety in plants, tank, manhole and tunnel construction.
Features
- Convert to 32 types gas’s concentration*
- Robust design
- Wide range models
- Up to five combustible gases can be set as target gas (option)
- Selectable power supply: alkaline AA batteries / rechargeable nickel metal hydride AA batteries
- Timer and stopwatch function
Specifications
Sampling Method | Extractive | |
Alarm Method | Gas Alarm | Beeping with flashing red light and AL icon on the LCD |
Device Error | Beeping with flashing yellow light and error message on the LCD | |
Power Source | ・Non-rechargeable alkaline AA battery x4: Toshiba LR6, Panasonic LR6X, Duracell MN1500, Energizer E91 or Varta 4106 ・Rechargeable nickel metal hydride AA battery x4: New Cosmos HR-3UTG | |
Operating Temperature/Humidity | -20 to 50℃ 95%RH. No condensation | |
Compliance*1 | ATEX: Ex II 1G Ex ia da IIC T4 Ga*1 IECEx: Ex ia da IIC T4 Ga*1 CE (ATEX, RoHS and RE directives) | |
Ingress Protection | IP67 | |
Main Features | Self-diagnosis (sensor error), Zero adjustment, Battery level indication, Flashlight, Peak-hold, LCD backlight, Audio alarm muting during gas alarm, Time indication, Alarm test, Alarm volume change, Audio muting | |
Dimensions | W91 x H164 x D44mm | |
Mass | Approx. 460g (including batteries) | |
Accessaries | Gas sampling tube(1m), Shoulder strap, Drain filter, Filter element, Alkaline AA batteries(or Rechargeable nickel metal hydride AA batteries) x 4, Screen protector film x 3 |
Approvals
Selectable Gases
Oxygen【O2】, Combustible gas
Gas Leak Detector
XP-702III
Application
Inspection for leaks from gas outlets, rubber tubes and pipe joints of gas pipes and air conditioners.
Features
- Smaller and Lighter. Reduced 50% in volume and 30% in weight from the conventional models.
- Easy-to-see LCD with display of battery life and sound effect settings of alarm and operation.
- Easy to notice the alarm by flashing 2 alarm lamps at hand.
- As little as 10 ppm can be detected(30ppm for Freon gas).
- Capable of Detecting 2 Gases (Target models: XP-702III-A, XP-702III-F)
Specifications
Detection Principle | Hot-wire semiconductor | ||
Detectable Leak Rate | Town gas, LPG, ets.: 3.3 x 10-6Pa.m3/s CFCs: [R407C] 12.4g/year [R410A] 11.2g/year | ||
Detectable Concentration | 10ppm (CFCs: 30ppm) | ||
Response Time | Within 3 seconds (except for CFCs) | ||
Power Source | Size AA alkaline battery (LR6) x 2 | ||
Battery Life | Approx. 12 hours (with size AA alkaline batteries at 25 °C) | ||
Explosion-proof Structure | Ex ia II BT3 (intrinsically safety) | ||
Operating Temperature
/Humidity | -20 to +50 °C, less than 85%RH (with no condensation) | ||
Dimensions | W38 x H130 x D32 mm (excluding protrusions) | ||
Weight | Approx. 190g (including batteries and soft case) | ||
Accessories | Soft case, Drain filter, Filter element, Gas probe, Dust filter, Hand strap,
2 x AA alkaline battery, Instruction manual | ||
Optional Accessories | Annealed copper tube, Gas collector, Sampling hose, etc. |
Approvals
Selectable Gases
acethylene【C2H2】, ammonia【NH3】, isobutane【i-C4H10】, isopropyl alcohol【(CH3)2CHOH】, carbon monoxide【CO】, ethylene【C2H4】, LPG, vinyl chloride【CH2=CHCI】, gasoline, xylene【C6H4(CH3)2】, oxidized ethylene【CH2CH2O】, propylene oxide【C3H6O】, cyclopentane【C5H10】, 1,2-Dichloroethane【ClCH2CH2Cl】, dimethyl ether【C2H6O】, hydrogen【H2】, city gas, propane【C3H8】, propylene【C3H6】, benzene【C6H6】, n-pentane【CH3(CH2)3CH3】, methane【CH4】, R-22【CHClF2】 etc.
Gas Leak Detector
XP-703DIII
Application
- For gas leak inspection at semiconductor factory where there is toxic gas.
- Safety for hydrogen-related equipment.
Features
- Can detect trace amounts of various semiconductor manufacturing gases.
- Automatic stop pump function
- Automatic gas exhaust mode
- Equivalent to IP22 (in soft case)
Specification
Model | XP-703DIII |
Gas Detected | Hydrogen, Arsine, Diborane, Silane and Phosphine |
Detection Principle | Hot wire semiconductor sensor |
Sampling Method | Extractive |
Detectable Leak Rate | H2: 5.07 x 10-7, AsH3: 2.53 x 10-7, B2H6: 1.01 x 10-7, SiH4: 2.53 x 10-7, PH3: 1.52 x 10-7 |
Detectable Gas Concentration | H2: 1.0ppm, AsH3: 0.5ppm, B2H6: 0.2ppm, SiH4: 0.5ppm, PH3: 0.3ppm |
Response Time | Within 10 seconds (for 300% of detectable gas concentration) |
Power Supply | Size AA alkaline batteries x 2 |
Battery Life*1 | Approx. 12 hours (with size AA alkaline batteries) |
Degree of Protection | Equivalent to IP22 |
Operating Pressure | Atmospheric pressure (800 to 1100 hPa) |
Operating Temperature/Humidity | 0 to +40°C Less than 85%RH (with no condensation) |
Dimensions | Approx. W38 x H130 x D32 mm (excluding protrusions) |
Weight | Approx. 190g (including batteries and soft case) |
Accessories | Soft case, Drain Filter, Replacement Filter, Gas Probe, Dust Filter, Hand Strap, Size AA Alkaline Battery x 2, etc. |
*1 It may vary based on the environmental conditions, operating conditions, strage time, battery manufacturer, etc.
Approvals
Selectable Gas
arsine【AsH3】, dichlorosilane【SiH2Cl2】, diborane【B2H6】, hydrogen【H2】, semiconductor manufacturing gases, phosphine【PH3】, R407C, R410A