COMBUSTIBLE GAS DETECTORS

Combustible gas detectors are used in work places that use combustible gas in order to secure worker safety, detect the location of any leakage, and measure gas concentrations.

Multi Gas Detector

XP-3368II-W / XP-3368II / XP-3318II

Application

For daily check and safety in plants, tank, manhole and tunnel construction.

Features

  • Convert to 32 types gas’s concentration*
  • Robust design
  • Wide range models
  • Up to five combustible gases can be set as target gas (option)
  • Selectable power supply: alkaline AA batteries / rechargeable nickel metal hydride AA batteries
  • Timer and stopwatch function

Specifications

Sampling MethodExtractive
Alarm MethodGas AlarmBeeping with flashing red light and AL icon on the LCD
Device ErrorBeeping with flashing yellow light and error message on the LCD
Power Source・Non-rechargeable alkaline AA battery x4: Toshiba LR6, Panasonic LR6X, Duracell MN1500, Energizer E91 or Varta 4106
・Rechargeable nickel metal hydride AA battery x4: New Cosmos HR-3UTG
Operating Temperature/Humidity-20 to 50℃ 95%RH. No condensation
Compliance*1ATEX: Ex II 1G Ex ia da IIC T4 Ga*1
IECEx: Ex ia da IIC T4 Ga*1
CE (ATEX, RoHS and RE directives)
Ingress ProtectionIP67
Main FeaturesSelf-diagnosis (sensor error), Zero adjustment, Battery level indication, Flashlight, Peak-hold, LCD backlight, Audio alarm muting during gas alarm, Time indication, Alarm test, Alarm volume change, Audio muting
DimensionsW91 x H164 x D44mm
MassApprox. 460g (including batteries)
AccessariesGas sampling tube(1m), Shoulder strap,  Drain filter, Filter element, Alkaline AA batteries(or Rechargeable nickel metal hydride AA batteries) x 4, Screen protector film x 3

Approvals

ATEX_logo CE_logo

Selectable Gases

Oxygen【O2】, Combustible gas

Gas Leak Detector

XP-702III

Application

Inspection for leaks from gas outlets, rubber tubes and pipe joints of gas pipes and air conditioners.

Features

  • Smaller and Lighter. Reduced 50% in volume and 30% in weight from the conventional models.
  • Easy-to-see LCD with display of battery life and sound effect settings of alarm and operation.
  • Easy to notice the alarm by flashing 2 alarm lamps at hand.
  • As little as 10 ppm can be detected(30ppm for Freon gas).
  • Capable of Detecting 2 Gases (Target models: XP-702III-A, XP-702III-F)

Specifications

Detection PrincipleHot-wire semiconductor
Detectable Leak RateTown gas, LPG, ets.: 3.3 x 10-6Pa.m3/s
CFCs: [R407C] 12.4g/year [R410A] 11.2g/year
Detectable Concentration10ppm (CFCs: 30ppm)
Response TimeWithin 3 seconds (except for CFCs)
Power SourceSize AA alkaline battery (LR6) x 2
Battery LifeApprox. 12 hours (with size AA alkaline batteries at 25 °C)
Explosion-proof StructureEx ia II BT3 (intrinsically safety)
Operating Temperature

 

/Humidity

-20 to +50 °C, less than 85%RH (with no condensation)
DimensionsW38 x H130 x D32 mm (excluding protrusions)
WeightApprox. 190g (including batteries and soft case)
AccessoriesSoft case, Drain filter, Filter element, Gas probe, Dust filter, Hand strap,

 

2 x AA alkaline battery, Instruction manual

Optional AccessoriesAnnealed copper tube, Gas collector, Sampling hose, etc.

Approvals

CE_logo

Selectable Gases

acethylene【C2H2】, ammonia【NH3】, isobutane【i-C4H10】, isopropyl alcohol【(CH3)2CHOH】, carbon monoxide【CO】, ethylene【C2H4】, LPG, vinyl chloride【CH2=CHCI】, gasoline, xylene【C6H4(CH3)2】, oxidized ethylene【CH2CH2O】, propylene oxide【C3H6O】, cyclopentane【C5H10】, 1,2-Dichloroethane【ClCH2CH2Cl】, dimethyl ether【C2H6O】, hydrogen【H2】, city gas, propane【C3H8】, propylene【C3H6】, benzene【C6H6】, n-pentane【CH3(CH2)3CH3】, methane【CH4】, R-22【CHClF2】 etc.

Gas Leak Detector

XP-703DIII

Application

  • For gas leak inspection at semiconductor factory where there is toxic gas.
  • Safety for hydrogen-related equipment.

Features

  • Can detect trace amounts of various semiconductor manufacturing gases.
  • Automatic stop pump function
  • Automatic gas exhaust mode
  • Equivalent to IP22 (in soft case)

Specification

ModelXP-703DIII
Gas DetectedHydrogen, Arsine, Diborane, Silane and Phosphine
Detection PrincipleHot wire semiconductor sensor
Sampling MethodExtractive
Detectable Leak
Rate
H2: 5.07 x 10-7, AsH3: 2.53 x 10-7, B2H6: 1.01 x 10-7, SiH4: 2.53 x 10-7,
PH3: 1.52 x 10-7
Detectable Gas
Concentration
H2: 1.0ppm, AsH3: 0.5ppm, B2H6: 0.2ppm, SiH4: 0.5ppm, PH3: 0.3ppm
Response TimeWithin 10 seconds (for 300% of detectable gas concentration)
Power SupplySize AA alkaline batteries x 2
Battery Life*1Approx. 12 hours
(with size AA alkaline batteries)
Degree of ProtectionEquivalent to IP22
Operating PressureAtmospheric pressure (800 to 1100 hPa)
Operating
Temperature/Humidity
0 to +40°C
Less than 85%RH (with no condensation)
DimensionsApprox. W38 x H130 x D32 mm (excluding protrusions)
WeightApprox. 190g (including batteries and soft case)
AccessoriesSoft case, Drain Filter, Replacement Filter, Gas Probe, Dust Filter, Hand Strap,
Size AA Alkaline Battery x 2, etc.

*1 It may vary based on the environmental conditions, operating conditions, strage time, battery manufacturer, etc.

Approvals

CE_logo

Selectable Gas

arsine【AsH3】, dichlorosilane【SiH2Cl2】, diborane【B2H6】, hydrogen【H2】, semiconductor manufacturing gases, phosphine【PH3】, R407C, R410A

OXYGEN INDICATORS

Oxygen concentration meters secure worker safety in locations where there is a danger of oxygen deficiency. We offers a rich lineup to match your applications, including compact, light-weight, wearable real-time oxygen meters and drop-down type that can check safety before work, for example through a manhole.

Oxygen Indicator

XP-3380II / XP-3380II-E

Application

For daily check and safety in plants, tank, manhole and tunnel construction.

Features

  • Robust design
  • Selectable power supply: alkaline AA batteries / rechargeable nickel metal hydride AA batteries
  • Timer and stopwatch function

Specifications

Sampling MethodExtractive
Alarm MethodGas AlarmBeeping with flashing red light and AL icon on the LCD
Device ErrorBeeping with flashing yellow light and error message on the LCD
Power Source・Non-rechargeable alkaline AA battery x4: Toshiba LR6, Panasonic LR6X, Duracell MN1500, Energizer E91 or Varta 4106
・Rechargeable nickel metal hydride AA battery x4: New Cosmos HR-3UTG
Operating Temperature/Humidity-20 to 50℃ 95%RH. No condensation
Compliance*1ATEX: Ex II 1G Ex ia IIC T4 Ga*1
IECEx: Ex ia IIC T4 Ga*1
CE (ATEX, RoHS and RE directives)
Ingress ProtectionIP67
Main FeaturesSelf-diagnosis (sensor error), Zero adjustment, Battery level indication, Flashlight, Peak-hold, LCD backlight, Audio alarm muting during gas alarm, Time indication, Alarm test, Alarm volume change, Audio muting
DimensionsW91 x H164 x D44mm
MassApprox. 460g (including batteries)
AccessariesGas sampling tube(1m), Shoulder strap,  Drain filter, Filter element, Alkaline AA batteries(or Rechargeable nickel metal hydride AA batteries) x 4, Screen protector film x 3
Oxygen Indicator
ModelXP-3380II (-E)*4
Target GasOxygen
Detection PrincipleGalvanic cell
Measure Range
(Reference Indication)
0–25vol%
(25.1–50.0vol%)
Accuracy*2±0.3%F.S.
Resolution0.1vol%
Alarm Set Value18vol%
Response Time
Continuous Operation Time*3Approx. 100 hours

*1When using alkaline AA batteries. Please contact us for full information.

*2 Under an identical measurement condition.

*3 At 25℃, with no alarm and backlight off. The time varies according to the circumstances, condition of use, storage period, battery manufacturer, etc.

*4 With cooling drain filter.

Approvals

ATEX_logo CE_logo

Selectable Gases

Oxygen【O2】

Personal Oxygen Monitor

XO-2200

Application

  • For safety check by wearing in tank, manhole, tunnel construction, hold and bottom etc.
  • For safety of site workers.

Features

  • Can be used continuously for 5000 hours.
  • Available with loud buzzer, alarm lamp from 4 dimensions, peak hold function.
  • Thin, lightweight design.

Simple gas leak detector which is perfect for tracing small gas leaks.

Specifications

ModelXO-2200
Gas DetectedOxygen
Detection PrincipleGalvanic cell
Sampling MethodDiffusion
Detection Range

 

(Service Range)

0 to 25 vol%

 

(25 to 50 vol%)

Resolution0.1vol%
Indication Accuracy*1Within ±0.5vol%
Alarm Set Value1st stage: 19.5vol%
2nd stage: 18.0vol%
Response Time*220s or less
Display ModeLCD (Manual backlight)
Alarm ModeBuzzer sounds, flashing red light, vibrator
ApprovalsEx ib IIB T3 (TIIS)
FunctionRemaining battery level, peak hold, memory of peak value,
alarm functions except gas alarm (sensor malfunction, remaining
battery level, air-adjustment malfunction)
Operation Temperature-10 to +40 °C, 30 to 90 %RH (non-condensing)
Operation Air PressureAir pressure ±10%
Power Source1 x AAA alkaline dry cell (LR 03)
Battery Life*3Up to 5000 hours (at 20°C without alarm)
DimensionsW65 x H64 x D22 mm (excluding protrusions)
WeightApprox. 75g (including batteries)
Standard Accessories1 x AAA alkaline dry cell, 1 x safety pin adaptor (with fixing screw)

*1 Under identical measuring conditions.

*2 Assuming 90% response and operating at 20 ±2°C.

*3 Battery life may vary with ambient conditions, conditions of use, storage period, battery manufactures, etc.

Approvals

CE_logo

Type Approved by TIIS Explosion-proof certification

Selectable Gases

oxygen【O2】

Digital Oxygen Indicator

XO-326IIs

Application

  • For safety check by wearing in tank, manhole, tunnel construction, hold and bottom etc.
  • For safety of site workers.

Features

  • Continuously for up to 15,000 hours with 2 x AA alkaline batteries
  • Automatic Air Adjustment
  • Plug-in sensor installed

Simple gas leak detector which is perfect for tracing small gas leaks.

Specifications

Gas DetectedOxygen
Detection PrincipleGalvanic cell
Sampling MethodDiffusion Type
Detection Range

 

(Service Range)

0 to 25.0 vol%

 

(25.1 to 40.0 vol%)

Indication AccuracyWithin ±0.5vol%
Display Resolution0.1vol%
Alarm Set Value1st stage: 19.5vol%
2nd stage: 18.0vol%
Response TimeWithin 20 seconds
Alarm FunctionBuzzer sounds, Red lamp blicks, LCD display blincks (latching),
Vibration (for vibration specifications
Power Source2 x size AA alkaline battery (LR6/ made by PANASONIC)
Continuous UseApprox. 15,000 hours
Explosion-Proof
Structure
Ex ia II CT3 X (Japan)
Protection ClassIP20 or equivalent
Operation Temperature/Humidity-10 to +40 °C

 

30 to 85 %RH (non condensing)

Approvals

Type Approved by TIIS Explosion-proof certification

Conforms to JIS T 8201

The Ship Equipment Inspection Society of Japan (HK) approved product (Designation required)

Type Approved by TIIS Explosion-proof certification

Selectable Gases

oxygen【O2】

TOXIC GAS DETECTOR

Toxic gas detectors are used in work places that use toxic gas in order to secure worker safety, detect the location of any leakage, and measure gas concentrations.

Personal CO Monitor

XC-2200

Application

  • For safety check by wearing at steel mills, construction site, tunnel construction and paint job site etc.
  • For safety of site workers.

Features

  • Can be used continuously for 5000 hours.
  • Available with loud buzzer, alarm lamp from 4 dimensions, peak hold function.
  • Available with TWA (Time Weighted Average) gas concentration display, memory of peak value, and peak hold   function.
  • Thin, lightweight design.

Pocket-sized personal carbon monoxide detector

Specifications

ModelXC-2200
Gas DetectedCarbon Monoxide
Detection PrincipleElectrochemical cell
Sampling MethodDiffusion
Detection Range
(Service Range)
0 to 300 ppm
(300 to 2,000 ppm)
Resolution0-350ppm: 1ppm
350-2,000ppm: 50ppm
Indication Accuracy*1Within ±30%
Alarm Set Value50ppm (first stage), 150ppm (second stage),
150ppm・h (time weighted average)
Response Time*230s or less (90% of final reading)
Display ModeLCD (Manual backlight)
Alarm ModeBuzzer sounds, flashing red light, vibrator
ApprovalsEx ib IIB T3 (TIIS)
FunctionsRemaining battery level, peak hold, peak value memory, readout
of time weighted average, alarm functions except gas alarm (time
weighted average value, sensor malfunction, remaining battery level,
zero-adjustment malfunction)
Operation Temperature-10°C to +40 °C, 30 to 90 %RH (non-condensing)
Operation Air PressureAir pressure ±10%
Power Source1 x AAA alkaline dry cell
Battery Life*3Up to 5000 hours (at 20°C with less than 20ppm)
DimensionsW65 x H64 x D22 mm (excluding protrusions)
WeightApprox. 75g (including battery)
Standard Accessories1 x AAA alkaline dry cell, 1 x safety pin adaptor (with fixing screw)

*1 Under identical measuring conditions.

*2 Operating at 20 ±2°C.

*3 Battery life may vary with ambient conditions, conditions of use, storage period, battery manufactures, etc.

Approvals

CE_logo

Type Approved by TIIS Explosion-proof certification

Selectable Gases

carbon monoxide【CO】

Personal H2S Monitor

XS-2200

Application

  • For safety check by wearing at incineration plant, sewerage facility and petrochemical plant.
  • For safety of site workers.

Features

  • Can be used continuously for 5000 hours.
  • Available with loud buzzer, alarm lamp from 4 dimensions, peak hold function.
  • Available with TWA (Time Weighted Average) gas concentration display, memory of peak value, and peak hold   function.
  • Thin, lightweight design.

Pocket-sized personal hydrogen sulfide detector.

Specifications

ModelXS-2200
Gas DetectedHydrogen Sulfide
Detection PrincipleElectrochemical cell
Sampling MethodDiffusion
Detection Range

 

(Service Range)

0 to 30.0 ppm

 

(30.1 to 100 ppm)

Resolution0-35.0ppm:0.1ppm
35-100ppm: 5ppm
Indication Accuracy*1Within ±1.5ppm ±1digit
Alarm Set Value1st stage: 10.0ppm
2nd stage: 15.0ppm
Response Time*230s or less
Display ModeLCD (Manual backlight)
Alarm ModeBuzzer sounds, flashing red light, vibrator
ApprovalsEx ib IIB T3 (TIIS)
FunctionsRemaining battery level, peak hold, memory of peak value,
alarm functions except gas alarm (sensor malfunction, remaining battery level,air-adjustment malfunction)
Operation Temperature-10°C to +40 °C, 30 to 85 %RH (non-condensing)
Operation Air PressureAir pressure ±10%
Power Source1 x AAA alkaline dry cell
Battery Life*3Up to 5000 hours (at 20°C with less than 5ppm)
DimensionsW65 x H64 x D22 mm (excluding protrusions)
WeightApprox. 75g (including battery)
Standard Accessories1 x AAA alkaline dry cell, 1 x safety pin adaptor (with fixing screw)

*1 Under identical measuring conditions.

*2 Operating at 20 ± 2°C.

*3 Battery life may vary with ambient conditions, conditions of use, storage period, battery manufactures, etc.

Approvals

CE_logo

Type Approved by TIIS Explosion-proof certification

Selectable Gases

hydrogen sulfide【H2S】

Portable Semiconductor Gas Detector

XPS-7II

Application

For gas leak inspection and concentration measurement at semiconductor factory where there is toxic gas

Features

  • World’s Smallest Portable Gas Detector for NF3 Detection. NF3 can be detected without any optional equipment.
  • The calibrated gas sensor unit can be replaced on site, reducing maintenance work.
  • Large LCD
  • 2-way power supply : Dry batteries and AC power supply (optional)
  • Small and lightweight
  • The speed of alarm sound changes depending on gas concentration.

Various semiconductor gases can be detected by changing the sensor unit.

Specifications

Detection PrincipleElectrochemical, Electrochemical + pyrolyzer
Target GasSemiconductor gases
Sampling MethodExtractive
Measuring RangeAs per delivery specifications
Accuracy *1±10%F.S. except for XDS-7NF
-30%F.S. to +10%F.S. for XDS-7NF
Response time *1T60: Less than 60 seconds
DisplayFour-digit on LCD
Power SourceAlkaline AA battery x 4pcs or Dedicated 100-240VAC/6VDC adapter (optional) *3
Continuous Operating Time*2More than 12 hours except for XDS-7NF
More than 8 hours for XDS-7NF
(by alkaline AA batteries (Toshiba LR6AN) at 20℃, with no gas alarm)
Operating Temperature and Humidity0 to +40ºC, 30 to 85%RH
ComplianceCE (EMC: 2014/30/EU) *3 *4
DimensionsApprox. W62 × H150 × D128 mm (excluding protrusions)
MassApprox. 1.3 kg

*1. Under identical conditions.
*2. The operating time (battery life) may vary depending on environment and conditions of use, storage period, battery manufacturer etc.
*3. AC power adapter does not comply with CE marking.
*4. There are two types of EC-7 sensor stocker, global and domestic (for use in Japan). Global type is CE-marked.

Approvals

CE_logo

Type Approved by TIIS Explosion-proof certification

Selectable Gases

ammonia【NH3】,silane【SiH4】,dichlorosilane【SiH2Cl2】, arsine【AsH3】,phosphine【PH3】,diborane【B2H6】,hydrogen selenide【H2Se】,germane【GeH4】,chlorine【Cl2】,chlorine trifluoride【ClF3】,hydrogen chloride【HCI】,hydrofluoric fluoride【HF】,hydrogen bromide【HBr】,nitrogen monoxide【NO】,hydrogen sulfide【H2S】,carbon monoxide【CO】,disilane【Si2H6】,fluorine【F2】,ozone【O3】,nitrogen trifloride【NO3】

Portable Semiconductor Gas Detector

XPS-7

Application

For gas leak inspection and concentration measurement at semiconductor factory where there is toxic gas.

Features

  • A single XPS-7 can be used for a variety of semiconductor gases, simply by changing the sensor unit.
  • Cassette-type sensor units eliminate calibration.

Can be used for a variety of semiconductor gases by changing a plug and play gas sensor.

Specifications

ModelXPS-7
Detection PrincipleElectrochemical cell
Gas DetectedSemiconductor gases
Sampling MethodExtractive
Detection RangeDepends on the specifications
Resolution1/100 of full scale
Indication Accuracy±10% of full scale
Alarm Mode2nd stage alarm type
Alarm IndicationIntermittent buzzer, flashing lamp
Response Time60s or less (60% response)
Operating Temperature0 to 40°C
Power Source4 x AA alkaline dry cells (*1) or an AC adaptor
Battery Life*2Up to 12 hours (by alkaline dry cells at 20℃ without alarms)
DimensionsW62 x H150 x D128mm (excluding protrusions)
WeightApprox. 1.3kg
Standard AccessoriesGas sampling hose with probe, shoulder strap, 4 x AA alkaline dry
cells, Spare filters
Optional AccessoriesAC adaptor (100 VAC/6 VDC), sensor stocker, log data collection kit

*1 Under identical measuring conditions.
*2 Battery life may vary with ambient conditions, conditions of use, storage period, battery manufactures, etc.

Approvals

CE_logo

Selectable Gases

arsine【AsH3】, ammonia【NH3】, carbon monoxide【CO】, nitric oxide【NO】, hydrogen chloride【HCI】, chlorine【Cl2】, ozone【O3】, chlorine trifluoride【ClF3】, dichlorosilane【SiH2Cl2】, disilane【Si2H6】, diborane【B2H6】, hydrogen bromide【HBr】, hydrogen selenide【H2Se】, sulfur dioxide【SO2】, nitrogen dioxide【NO2】, semiconductor manufacturing gases, hydrofluoric acid【HF】, fluorine【F2】, phosphine【PH3】, germane【GeH4】, silane【SiH4】, hydrogen sulfide【H2S】

MULTI GAS DETECTORS

Multi-gas detectors can detect multiple gases with a single detector. We offers a rich lineup that lets you select the combination of target gases to match your application.

Multi-Gas Detector

XA-4400II

Application

For safety check by wearing at construction site and steel plant, safety of site workers.

Features

  • 40 hours or more of continuous operation with a single AAA Battery (when used in long-life mode)
  • Compact and lightweight
    70 (W) x 72 (H) x 20 (D) mm, approx. 130g
  • Sounding alarm, three flashing lights and vibrations
    Alarm sound more than 95dB / 30cm
  • Ingress Protection is IP67
    Water and dust proof. Can be used outdoors on a rainy day
  • Intrinsically Safe (Ex ia II CT 3)
    Complies with hydrogen and acethylene explosion proof requirements
  • Sensor life of 2 years

Up to 4 gases of Oxygen/ Combustible gas/ Hydrogen sulfide/ Carbon monoxide can be measured at once with simultaneous display.

Specifications

Operating Temperature/Humidity-20 to +50 °C, 30 to 85 %RH (non condensing)
Continuous Use TimeApprox. 40 hours when the long-life mode is ON / Approx. 20 hours when the long-life mode is OFF
Approx. 1200 hours without combustible gas sensor (at 25 degrees C, without alarm,backlight OFF)
Power Source1 x AAA Panasonic alkaline battery
DisplayLCD
Gas AlarmBuzzer sound, Flashing RED lamp, Vibration, LCD (automatic recovery)
Intrinsically safeEx ibd IIC T3 (TIIS)
II 1 G Ex ia IIC T3 Ga (ATEX)
Class I, Zone 0, AEx ia IIC T3 Hazardous Locations. (UL) *pending
Ingress ProtectionIP67
FunctionSelf-diagnosis (sensor trouble), Automatic air adjustment, Remaining battery level,
Peak-hold, LCD backlight, Buzzer stop for gas alarm, Time & Temperature indication,
Alarm test, Buzzer volume, Silent mode, Long-life mode, Data logging (datalogger kitis necessary for logging)
DimensionsW70 x H72 x D26 mm (excluding protrusions)
WeightApprox. 130g (excluding battery)
AccessoriesSafety-Pin band, alkaline battery, 2 x filter element for replacement
OptionsDatalogger kit, soft case, belt clip

Approvals

ATEX_logo ULÏ°¸.ai*pending CE_logo

Type Approved by TIIS Explosion-proof certification

Selectable Gases

oxygen【O2】, carbon monoxide【CO】, hydrogen sulfide【H2S】, methane【CH4】 or isobutane【i-C4H10

Personal CO/O2 Monitor

XOC-2200

Application

  • For safety check by wearing at construction site and steel mills, safety of site workers.

Features

  • Can be used continuously for 5000 hours.
  • 3 types of Alarm: loud buzzer, alarm lamp and vibration.
  • Available with TWA (Time Weighted Average) concentration display, peak memory, and peak hold function.

Pocket-sized personal oxygen and carbon monoxide detector.

Specifications

Response Time*220s or less30s or less
Display ModeLCD (Manual backlight)
Alarm ModeBuzzer sounds, flashing red light, vibrator
ApprovalsEx ib IIB T3 (TIIS)
FunctionRemaining battery level, peak hold, peak value memory, readout of time

 

weighted average, remainig battery level, alarm functions except gas

alarm (time weighted average, sensor malfunction, battery level,

zero-adjustment malfunction), gas calibration, gas concentration indication

Operation Temperature-10°C to +40°C, 30 to 90 %RH (non-condensing)
Operation Air PressureAir pressure ±10%
Power Source1 x AAA alkaline dry cell
Battery Life*3Up to 5,000 hours (at 20°C with less than 20ppm of CO and more than

 

20.3vol% of O2)

DimensionsW65 x H64 x D22mm (excluding protrusions)
WeightApprox. 75g (including batteries)
Standard Accessories1 x AAA alkaline dry cell, 1 x safety pin adaptor (with fixing screw)

*1 Under identical measuring conditions.
*2 Operating at 20 ±2°C.
*3 Battery life may vary with ambient conditions, conditions of use, storage period, battery manufactures, etc.

Approvals

CE_logo

Type Approved by TIIS Explosion-proof certification

Selectable Gases

oxygen【O2】, Carbon monoxide【CO】

Personal H2S/O2 Monitor

XOS-2200

Application

  • For safety check before working in underground construction site in the tank, manhole and tunnel etc.
  • For safety of site workers.

Features

  • Can be used continuously for 5000 hours.
  • 3 types of Alarm: loud buzzer, alarm lamp and vibration.
  • Thin, lightweight design.

Pocket-sized personal oxygen and hydrogen sulfide detector.

Specifications

ModelXOS-2200
Gas DetectedOxygen (O2)Hydrogen Sulfide (H2S)
Detection PrincipleGalvanic cellElectrochemical cell
Sampling MethodDiffusion
Detection Range
(Service Range)
0 to 25 vol%
(25 to 50 vol%)
0 to 30.0 ppm
(30.1 to 100 ppm)
Resolution0.1vol%0-35.0 ppm: 0.1ppm
35-100ppm: 5ppm
Indication Accuracy*1Within ±0.5vol%
±1 digit
Within ±1.5ppm
±1 digit
Alarm Set Value1st stage: 19.5vol%
2nd stage: 18.0vol%
1st stage: 10.0ppm
2nd stage: 15.0ppm
Response Time*220s or less30s or less
Display ModeLCD (Manual backlight)
Alarm ModeBuzzer sounds, flashing red light, vibrator
ApprovalsEx ib IIB T3 (TIIS)
FunctionRemaining battery level, peak hold, memory of peak value, alarm
functions except gas alarm (sensor malfunction, remaining battery
level, air-adjustment malfunction), gas concentration indication
Operation Temperature-10 to +40 °C, 30 to 85 %RH (non-condensing)
Operation Air PressureAir pressure ±10%
Power Source1 x AAA alkaline dry cell (LR03)
Battery Life*3Up to 5,000 hours (at 20°C without alarm)
DimensionsW65 x H64 x D22 mm (excluding protrusions)
WeightApprox. 75g (including batteries)
Standard Accessories1 x AAA alkaline dry cell, 1 x safety pin adaptor (with fixing screw)

*1 Under identical measuring conditions.

*2 Assuming 90% response and operating at 20 ±2°C.

*3 Battery life may vary with ambient conditions, conditions of use, storage period, battery manufactures, etc.

Approvals

CE_logo

Type Approved by TIIS Explosion-proof certification

Selectable Gases

oxygen【O2】, hydrogen sulfide【H2S】

Multi Gas Detector

XP-302M

Application

  • Daily inspections in various plants, safety of site workers.
  • For safety check before working in underground construction site in the tank, manhole and tunnel etc. and safety of site workers.

Features

  • Compact and Lightweight.
  • Large, blight display with automated backlight.
  • Monitors LEL, O2, CO and H2S

Oxygen/ Combustible gas/ Hydrogen sulfide/ Carbon monoxide can be measured at once with simultaneous display.

Specifications

Operating Temperature & Humidity-10 to +40 °C, 95%RH (non condensing)
Power Source4 x AA alkaline dry cells
DisplayA large LCD with backlight provides simultaneous and continuous readout of all gases being monitored.
3 user-selectable display modes (standard display / graphic display/English display).
Alarms90+ dB buzzer, flashing LCD and warning lamp
Battery Life*38+ hours on 4 x AA alkaline cells (20°C, no alarm, no backlight and

 

datalogging OFF)

Safety DesignIntrinsically safe design Exibd II BT3
Function・Automatic backlight (in dim light or alarm condition) ・Zero adjustment

 

・Peak hold ・Buzzer control・Low flow alarm ・Datalogging function

(up to 150 hours) ・Buzzer stop・Alarm test ・Display of remaining battery

level, current time and temperature

DimensionsW152 x H152 x D42 mm (excluding protrusions)
WeightApprox. 870g
  1. Under identical conditions
  2. T90
  3. It depends on the environmental conditions, service conditions, storage period, and battery manufacturers
  4. Non explosion-proof type
  5. Please contact our dealers / distributors for available accessories

Selectable Gases

oxygen【O2】, carbon monoxide【CO】, hydrogen sulfide【H2S】, methane【CH4】 or isobutane【i-C4H10】

INCOMPLETE COMBUSTION GAS DETECTORS (CO METER)

Combustion emission gas detectors are used for maintenance and inspections of combustion equipment and to measure combustion efficiency. These detectors pursue operability, are equipped with a wealth of functions, and achieve superior ease-of-use.

Carbon Monoxide Detector

XP-333IIA

Application

For measurement of carbon monoxide concentration in the combustion exhaust gas due to incomplete combustion of gas equipment.

Features

  • Detection range is 0 to 0.499vol% for CO
  • Compact and light weight
  • Detect at 3 patterns: Actual, Mean and Peak value
  • High sensitivity and selectivity sensor for CO3 different audible and visual alrm levels
  • 3 x AA alkaline batteries
  • Auto-Zero Adjustment
  • Including soft case

Suitable for maintenance of gas-fired boiler, gas water heater, etc.

Specifications

ModelXP-333IIA
Detection PrincipleElectrochemical cell
Sampling MethodExtractive
Measuring Range0 to 0.499 vol%
Response Time<14 sec. (T90 excluding sampling hose)
Operating Temperature-10 to +40 °C
Power Source3 x AA alkaline batteries
Battery Life TimeApprox. 100 hrs.
DimensionsW60 x H155 x D40 mm
WeightApprox. 270g (excluding batteries)

Selectable Gases

carbon monoxide【CO】

OTHERS

Real-time VOC monitor

XP-3120-V

Application

  • Oil & Gas
  • Industrial Safety
  • Environmental Measurement
  • Indoor Air Quality

Features

  • Compact and light-weight
  • Easy to use
  • Intrinsically safe: Ex ib d IIB T3 (TIIS)
  • Stable measurement with long-term proven sensor
  • Able to monitor concentration changes with data-logging function
  • Low initial cost

Portable VOC monitor suitable for on-site measurement of comprehensive VOCs.

Specifications

ModelXP-3120-V
Gas DetectedVOC (Calibration Gas: Toluene)
Sampling MethodExtractive
Detection PrincipleHot-wire semiconductor
Detection RangeLow range: 0 to 100 ppm
High range: 0 to 1000 ppm
Indication Accuracy± 10% of full scale
DisplayMain LCD: Digital-LCD with backlight
Sub LCD: Clock display
AlarmNon-alarm
Explosion-proof StructureEx ib d IIB T3 (TIIS)
Operation Temperature0 to +40 °C
Power Source4 x AA alkaline dry battery
Continuous OperationWith alkaline battery: approx 25 hours (at 20°C, backlight OFF)
DimensionsW82 x H162 x D36 mm
WeightApprox. 450g (excluding batteries)
Standard AccessoriesSoft case, 4 x AA alkaline dry battery, Gas sampling hose (1m, for solvent model SH-401),
Replacement filter, Probe with filter/moisture trap
Optional ItemsDatalogger kit (CD-ROM + USB cable), AC adaptor, Activated carbon filter set

Approvals

Type Approved by TIIS Explosion-proof certification

Type Approved by TIIS Explosion-proof certification

HCFC Detector

XP-704III

Application

For maintenance work of air conditioning.

Features

  • Most of refrigerant gases can be detected
  • Automatic stop pump function
  • Automatic gas exhaust mode
  • Equivalent to IP22 (in soft case)

A small leak of HCFC/HFC gas can be detected.

Specifications

ModelXP-704III
Gas DetectedR-22, R-32, R-404A, R-407C, R600a, R410A, R-134a, R-290,

 

HFO-1234yf

Detection PrincipleHot-wire semiconductor sensor
Sampling MethodExtractive
Detectable Leak Rate (annual)R-22: 2.84(g), R-32: 1.71(g), R-404A: 3.30(g), R-407C: 3.12(g),

 

R600a: 1.91(g), R410A: 2.82(g), R-134a: 20.09(g), R-290: 1.45(g),

HFO-1234yf: 3.74(g)

Detectable Gas Concentration5 ppm (R-134a: 30ppm)
Response TimeWithin 10 seconds
Power SupplySize AA alkaline batteries x 2
Battery Life*1Approx. 12 hours (with size AA alkaline batteries)
Degree of ProtectionEquivalent to IP22
Operating PressureAtmospheric pressure (800 to 1100 hPa)
Operating Temperature and
Humidity
0 to +40 °C
Less than 85%RH (with no condensation)
DimensionsW38 x H130 x D32 mm (excluding protrusions)
WeightApprox. 190g (including batteries and soft case)
AccessoriesSoft case, Drain Filter, Replacement Filter, Gas Probe, Dust Filter,
Hand Strap, Size AA Alkaline Battery x 2, etc.

*1 It may vary based on the environmental conditions, operating conditions, strage time, battery manufacturer, etc.

Approvals

CE_logo

Selectable Gases

R-22【CHClF2】, R-23【CHF3】, R-32【CH2F2】, R407C, R410A, R404A, R600a, R134a, R1234yf, combustible gas

Portable VOC Analyzer

XG-100V

Application

  • Measurement for VOC in indoor
  • VOC inspection of electrical appliances

Features

  • High sensitivity
    Low concentrations of the target gas can be analyzed and measured with high accuracy.
  • Field measurement
    Easily transportable to use on site.
  • No need of carrier gas.
  • Simple operation
    Simply inject the target gas into a gas inlet with a syringe or Auto Sampler Option.

Pocket-sized personal oxygen and hydrogen sulfide detector.

Specifications

ModelXG-100V
Substance MeasuredToluene, xylene, ethyl benzene and styrene
Measurement Range
(measuring toluene)
Minimum detection limit: 4mg/m3, 1ppb
Maximum detection limit: 3700mg/m3, 1000ppb
RepeatabilityWithin ±5% (RSD) (Toluene 70ppb)
Carrier GasAtmospheric air
Sample Injection MethodDirect injection by syringe (sample volume: 10ml)
Operating Temperature5 to 35 °C
Power Source100 VAC, 50/60 Hz
DimensionsW240 x H190 x D380 mm
WeightApprox. 10kg
Standard AccessoriesData analysis software (hardware requirement: Windows XP), calibration

 

gas, 3 x syringes for sample injection, AC power cable, RS232C cable,

USB-RS232C conversion cable, 8 x C alkaline dry cells.

Selectable Gases

toluene【C6H5CH3】, xylene【C6H4(CH3)2】, ethyl benzene【C6H5C2H5】, styrene【C6H5CH=CH2】

Grease Steel Dust Meter

SDM-72

Video

Application

  • Simple diagnosis and trend monitoring of the wear condition of greased bearings, gears, etc.
  • Pre-diagnosis for Ferrography method and SOAP method

Features

  • Able to diagnose the bearing condition, even long before wear-induced vibration becomes detectable, by measuring the amount of steel dust in the grease around the bearing.
  • Simple operation – simply measured by a grease sample

Oxygen/ Combustible gas/ Hydrogen sulfide/ Carbon monoxide can be measured at once with simultaneous display.

Specifications

ModelSDM-72
Measurement PrincipleMagnetic balance type electromagnetic method
Substance MeasuredSteel dust concentration in grease
Measurement Range0 to 5.000 %Wt
Minimum Resolusion0.001 %Wt
Zero adjustmentAutomatic adjustment
Amount of sampleApprox. 0.8ml
Power Source4 x AA (R6) alkaline drycells
Battery Life*1Up to 30 hours by alkaline cells
Operating temperature0 to +40 °C
DimensionsW84 x H190 x D40 mm
WeightApprox. 500g (including batteries)
Standard AccessoriesCarrying case, grease sampling spatula, grease sample case (10 pieces)   and 4 x AA (R6) alkaline drycells

*1 Battery life may vary with ambient conditions, conditions of use, storage period, battery manufacturers, etc.

Oil Steel Dust Checker

SDM-73

Video

Application

  • Simple diagnosis of the wear condition of bearings, gears, cylinders, etc. in rotational equipment
  • Monitoring steel dust contamination in hydraulic oil and grinding oil

Features

  • Able to diagnose the bearing condition, even long before wear-induced vibration becomes detectable, by measuring the amount of steel dust in the oil around the bearing.
  • Simple operation – simply measured by an oil sample

Able to diagnose the bearing condition, even long before wear-induced vibration becomes detectable, by measuring the amount of steel dust in the oil around the bearing.

Specifications

ModelSDM-73
Measurement PrincipleMagnetic balance type electromagnetic industion method
Substance MeasuredSteel dust concentration in lubricating oil
Measurement Range0 to 19999wt ppm
Minimum Resolusion1wt ppm
Zero adjustmentAutomatic adjustment
Amount of sample1.5ml
Power Source4 x AA (R6) alkaline drycells
Battery Life*1Up to 30 hours by alkaline cells
Operating temperature0 to 40 °C
DimensionsW84 x H190 x D40 mm
WeightApprox. 500g (including batteries)
Standard AccessoriesCarrying case, 2ml syringe (5 pieces), oil sampling nozzle (2 pieces),

 

syringe holder and 4 x AA (R6) alkaline drycells

  1. Battery life may vary with ambient conditions, conditions of use, storage period, battery manufacturers, etc.