COMBUSTIBLE GAS DETECTORS
Combustible gas detectors are used in work places that use combustible gas in order to secure worker safety, detect the location of any leakage, and measure gas concentrations.
Multi Gas Detector
XP-3368II-W / XP-3368II / XP-3318II
Application
For daily check and safety in plants, tank, manhole and tunnel construction.
Features
- Convert to 32 types gas’s concentration*
- Robust design
- Wide range models
- Up to five combustible gases can be set as target gas (option)
- Selectable power supply: alkaline AA batteries / rechargeable nickel metal hydride AA batteries
- Timer and stopwatch function
Specifications
Sampling Method | Extractive | |
Alarm Method | Gas Alarm | Beeping with flashing red light and AL icon on the LCD |
Device Error | Beeping with flashing yellow light and error message on the LCD | |
Power Source | ・Non-rechargeable alkaline AA battery x4: Toshiba LR6, Panasonic LR6X, Duracell MN1500, Energizer E91 or Varta 4106 ・Rechargeable nickel metal hydride AA battery x4: New Cosmos HR-3UTG | |
Operating Temperature/Humidity | -20 to 50℃ 95%RH. No condensation | |
Compliance*1 | ATEX: Ex II 1G Ex ia da IIC T4 Ga*1 IECEx: Ex ia da IIC T4 Ga*1 CE (ATEX, RoHS and RE directives) | |
Ingress Protection | IP67 | |
Main Features | Self-diagnosis (sensor error), Zero adjustment, Battery level indication, Flashlight, Peak-hold, LCD backlight, Audio alarm muting during gas alarm, Time indication, Alarm test, Alarm volume change, Audio muting | |
Dimensions | W91 x H164 x D44mm | |
Mass | Approx. 460g (including batteries) | |
Accessaries | Gas sampling tube(1m), Shoulder strap, Drain filter, Filter element, Alkaline AA batteries(or Rechargeable nickel metal hydride AA batteries) x 4, Screen protector film x 3 |
Approvals
Selectable Gases
Oxygen【O2】, Combustible gas
Gas Leak Detector
XP-702III
Application
Inspection for leaks from gas outlets, rubber tubes and pipe joints of gas pipes and air conditioners.
Features
- Smaller and Lighter. Reduced 50% in volume and 30% in weight from the conventional models.
- Easy-to-see LCD with display of battery life and sound effect settings of alarm and operation.
- Easy to notice the alarm by flashing 2 alarm lamps at hand.
- As little as 10 ppm can be detected(30ppm for Freon gas).
- Capable of Detecting 2 Gases (Target models: XP-702III-A, XP-702III-F)
Specifications
Detection Principle | Hot-wire semiconductor | ||
Detectable Leak Rate | Town gas, LPG, ets.: 3.3 x 10-6Pa.m3/s CFCs: [R407C] 12.4g/year [R410A] 11.2g/year | ||
Detectable Concentration | 10ppm (CFCs: 30ppm) | ||
Response Time | Within 3 seconds (except for CFCs) | ||
Power Source | Size AA alkaline battery (LR6) x 2 | ||
Battery Life | Approx. 12 hours (with size AA alkaline batteries at 25 °C) | ||
Explosion-proof Structure | Ex ia II BT3 (intrinsically safety) | ||
Operating Temperature
/Humidity | -20 to +50 °C, less than 85%RH (with no condensation) | ||
Dimensions | W38 x H130 x D32 mm (excluding protrusions) | ||
Weight | Approx. 190g (including batteries and soft case) | ||
Accessories | Soft case, Drain filter, Filter element, Gas probe, Dust filter, Hand strap,
2 x AA alkaline battery, Instruction manual | ||
Optional Accessories | Annealed copper tube, Gas collector, Sampling hose, etc. |
Approvals
Selectable Gases
acethylene【C2H2】, ammonia【NH3】, isobutane【i-C4H10】, isopropyl alcohol【(CH3)2CHOH】, carbon monoxide【CO】, ethylene【C2H4】, LPG, vinyl chloride【CH2=CHCI】, gasoline, xylene【C6H4(CH3)2】, oxidized ethylene【CH2CH2O】, propylene oxide【C3H6O】, cyclopentane【C5H10】, 1,2-Dichloroethane【ClCH2CH2Cl】, dimethyl ether【C2H6O】, hydrogen【H2】, city gas, propane【C3H8】, propylene【C3H6】, benzene【C6H6】, n-pentane【CH3(CH2)3CH3】, methane【CH4】, R-22【CHClF2】 etc.
Gas Leak Detector
XP-703DIII
Application
- For gas leak inspection at semiconductor factory where there is toxic gas.
- Safety for hydrogen-related equipment.
Features
- Can detect trace amounts of various semiconductor manufacturing gases.
- Automatic stop pump function
- Automatic gas exhaust mode
- Equivalent to IP22 (in soft case)
Specification
Model | XP-703DIII |
Gas Detected | Hydrogen, Arsine, Diborane, Silane and Phosphine |
Detection Principle | Hot wire semiconductor sensor |
Sampling Method | Extractive |
Detectable Leak Rate | H2: 5.07 x 10-7, AsH3: 2.53 x 10-7, B2H6: 1.01 x 10-7, SiH4: 2.53 x 10-7, PH3: 1.52 x 10-7 |
Detectable Gas Concentration | H2: 1.0ppm, AsH3: 0.5ppm, B2H6: 0.2ppm, SiH4: 0.5ppm, PH3: 0.3ppm |
Response Time | Within 10 seconds (for 300% of detectable gas concentration) |
Power Supply | Size AA alkaline batteries x 2 |
Battery Life*1 | Approx. 12 hours (with size AA alkaline batteries) |
Degree of Protection | Equivalent to IP22 |
Operating Pressure | Atmospheric pressure (800 to 1100 hPa) |
Operating Temperature/Humidity | 0 to +40°C Less than 85%RH (with no condensation) |
Dimensions | Approx. W38 x H130 x D32 mm (excluding protrusions) |
Weight | Approx. 190g (including batteries and soft case) |
Accessories | Soft case, Drain Filter, Replacement Filter, Gas Probe, Dust Filter, Hand Strap, Size AA Alkaline Battery x 2, etc. |
*1 It may vary based on the environmental conditions, operating conditions, strage time, battery manufacturer, etc.
Approvals
Selectable Gas
arsine【AsH3】, dichlorosilane【SiH2Cl2】, diborane【B2H6】, hydrogen【H2】, semiconductor manufacturing gases, phosphine【PH3】, R407C, R410A
OXYGEN INDICATORS
Oxygen concentration meters secure worker safety in locations where there is a danger of oxygen deficiency. We offers a rich lineup to match your applications, including compact, light-weight, wearable real-time oxygen meters and drop-down type that can check safety before work, for example through a manhole.
Oxygen Indicator
XP-3380II / XP-3380II-E
Application
For daily check and safety in plants, tank, manhole and tunnel construction.
Features
- Robust design
- Selectable power supply: alkaline AA batteries / rechargeable nickel metal hydride AA batteries
- Timer and stopwatch function
Specifications
Sampling Method | Extractive | |
Alarm Method | Gas Alarm | Beeping with flashing red light and AL icon on the LCD |
Device Error | Beeping with flashing yellow light and error message on the LCD | |
Power Source | ・Non-rechargeable alkaline AA battery x4: Toshiba LR6, Panasonic LR6X, Duracell MN1500, Energizer E91 or Varta 4106 ・Rechargeable nickel metal hydride AA battery x4: New Cosmos HR-3UTG | |
Operating Temperature/Humidity | -20 to 50℃ 95%RH. No condensation | |
Compliance*1 | ATEX: Ex II 1G Ex ia IIC T4 Ga*1 IECEx: Ex ia IIC T4 Ga*1 CE (ATEX, RoHS and RE directives) | |
Ingress Protection | IP67 | |
Main Features | Self-diagnosis (sensor error), Zero adjustment, Battery level indication, Flashlight, Peak-hold, LCD backlight, Audio alarm muting during gas alarm, Time indication, Alarm test, Alarm volume change, Audio muting | |
Dimensions | W91 x H164 x D44mm | |
Mass | Approx. 460g (including batteries) | |
Accessaries | Gas sampling tube(1m), Shoulder strap, Drain filter, Filter element, Alkaline AA batteries(or Rechargeable nickel metal hydride AA batteries) x 4, Screen protector film x 3 |
Oxygen Indicator
Model | XP-3380II (-E)*4 |
Target Gas | Oxygen |
Detection Principle | Galvanic cell |
Measure Range (Reference Indication) | 0–25vol% (25.1–50.0vol%) |
Accuracy*2 | ±0.3%F.S. |
Resolution | 0.1vol% |
Alarm Set Value | 18vol% |
Response Time | ー |
Continuous Operation Time*3 | Approx. 100 hours |
*1When using alkaline AA batteries. Please contact us for full information.
*2 Under an identical measurement condition.
*3 At 25℃, with no alarm and backlight off. The time varies according to the circumstances, condition of use, storage period, battery manufacturer, etc.
*4 With cooling drain filter.
Approvals
Selectable Gases
Oxygen【O2】
Personal Oxygen Monitor
XO-2200
Application
- For safety check by wearing in tank, manhole, tunnel construction, hold and bottom etc.
- For safety of site workers.
Features
- Can be used continuously for 5000 hours.
- Available with loud buzzer, alarm lamp from 4 dimensions, peak hold function.
- Thin, lightweight design.
Simple gas leak detector which is perfect for tracing small gas leaks.
Specifications
Model | XO-2200 |
Gas Detected | Oxygen |
Detection Principle | Galvanic cell |
Sampling Method | Diffusion |
Detection Range
(Service Range) | 0 to 25 vol%
(25 to 50 vol%) |
Resolution | 0.1vol% |
Indication Accuracy*1 | Within ±0.5vol% |
Alarm Set Value | 1st stage: 19.5vol% 2nd stage: 18.0vol% |
Response Time*2 | 20s or less |
Display Mode | LCD (Manual backlight) |
Alarm Mode | Buzzer sounds, flashing red light, vibrator |
Approvals | Ex ib IIB T3 (TIIS) |
Function | Remaining battery level, peak hold, memory of peak value, alarm functions except gas alarm (sensor malfunction, remaining battery level, air-adjustment malfunction) |
Operation Temperature | -10 to +40 °C, 30 to 90 %RH (non-condensing) |
Operation Air Pressure | Air pressure ±10% |
Power Source | 1 x AAA alkaline dry cell (LR 03) |
Battery Life*3 | Up to 5000 hours (at 20°C without alarm) |
Dimensions | W65 x H64 x D22 mm (excluding protrusions) |
Weight | Approx. 75g (including batteries) |
Standard Accessories | 1 x AAA alkaline dry cell, 1 x safety pin adaptor (with fixing screw) |
*1 Under identical measuring conditions.
*2 Assuming 90% response and operating at 20 ±2°C.
*3 Battery life may vary with ambient conditions, conditions of use, storage period, battery manufactures, etc.
Approvals
Type Approved by TIIS Explosion-proof certification
Selectable Gases
oxygen【O2】
Digital Oxygen Indicator
XO-326IIs
Application
- For safety check by wearing in tank, manhole, tunnel construction, hold and bottom etc.
- For safety of site workers.
Features
- Continuously for up to 15,000 hours with 2 x AA alkaline batteries
- Automatic Air Adjustment
- Plug-in sensor installed
Simple gas leak detector which is perfect for tracing small gas leaks.
Specifications
Gas Detected | Oxygen | ||
Detection Principle | Galvanic cell | ||
Sampling Method | Diffusion Type | ||
Detection Range
(Service Range) | 0 to 25.0 vol%
(25.1 to 40.0 vol%) | ||
Indication Accuracy | Within ±0.5vol% | ||
Display Resolution | 0.1vol% | ||
Alarm Set Value | 1st stage: 19.5vol% 2nd stage: 18.0vol% | ||
Response Time | Within 20 seconds | ||
Alarm Function | Buzzer sounds, Red lamp blicks, LCD display blincks (latching), Vibration (for vibration specifications | ||
Power Source | 2 x size AA alkaline battery (LR6/ made by PANASONIC) | ||
Continuous Use | Approx. 15,000 hours | ||
Explosion-Proof Structure | Ex ia II CT3 X (Japan) | ||
Protection Class | IP20 or equivalent | ||
Operation Temperature/Humidity | -10 to +40 °C
30 to 85 %RH (non condensing) |
Approvals
Type Approved by TIIS Explosion-proof certification
Conforms to JIS T 8201
The Ship Equipment Inspection Society of Japan (HK) approved product (Designation required)
Type Approved by TIIS Explosion-proof certification
Selectable Gases
oxygen【O2】
TOXIC GAS DETECTOR
Toxic gas detectors are used in work places that use toxic gas in order to secure worker safety, detect the location of any leakage, and measure gas concentrations.
Personal CO Monitor
XC-2200
Application
- For safety check by wearing at steel mills, construction site, tunnel construction and paint job site etc.
- For safety of site workers.
Features
- Can be used continuously for 5000 hours.
- Available with loud buzzer, alarm lamp from 4 dimensions, peak hold function.
- Available with TWA (Time Weighted Average) gas concentration display, memory of peak value, and peak hold function.
- Thin, lightweight design.
Pocket-sized personal carbon monoxide detector
Specifications
Model | XC-2200 |
Gas Detected | Carbon Monoxide |
Detection Principle | Electrochemical cell |
Sampling Method | Diffusion |
Detection Range (Service Range) | 0 to 300 ppm (300 to 2,000 ppm) |
Resolution | 0-350ppm: 1ppm 350-2,000ppm: 50ppm |
Indication Accuracy*1 | Within ±30% |
Alarm Set Value | 50ppm (first stage), 150ppm (second stage), 150ppm・h (time weighted average) |
Response Time*2 | 30s or less (90% of final reading) |
Display Mode | LCD (Manual backlight) |
Alarm Mode | Buzzer sounds, flashing red light, vibrator |
Approvals | Ex ib IIB T3 (TIIS) |
Functions | Remaining battery level, peak hold, peak value memory, readout of time weighted average, alarm functions except gas alarm (time weighted average value, sensor malfunction, remaining battery level, zero-adjustment malfunction) |
Operation Temperature | -10°C to +40 °C, 30 to 90 %RH (non-condensing) |
Operation Air Pressure | Air pressure ±10% |
Power Source | 1 x AAA alkaline dry cell |
Battery Life*3 | Up to 5000 hours (at 20°C with less than 20ppm) |
Dimensions | W65 x H64 x D22 mm (excluding protrusions) |
Weight | Approx. 75g (including battery) |
Standard Accessories | 1 x AAA alkaline dry cell, 1 x safety pin adaptor (with fixing screw) |
*1 Under identical measuring conditions.
*2 Operating at 20 ±2°C.
*3 Battery life may vary with ambient conditions, conditions of use, storage period, battery manufactures, etc.
Approvals
Type Approved by TIIS Explosion-proof certification
Selectable Gases
carbon monoxide【CO】
Personal H2S Monitor
XS-2200
Application
- For safety check by wearing at incineration plant, sewerage facility and petrochemical plant.
- For safety of site workers.
Features
- Can be used continuously for 5000 hours.
- Available with loud buzzer, alarm lamp from 4 dimensions, peak hold function.
- Available with TWA (Time Weighted Average) gas concentration display, memory of peak value, and peak hold function.
- Thin, lightweight design.
Pocket-sized personal hydrogen sulfide detector.
Specifications
Model | XS-2200 |
Gas Detected | Hydrogen Sulfide |
Detection Principle | Electrochemical cell |
Sampling Method | Diffusion |
Detection Range
(Service Range) | 0 to 30.0 ppm
(30.1 to 100 ppm) |
Resolution | 0-35.0ppm:0.1ppm 35-100ppm: 5ppm |
Indication Accuracy*1 | Within ±1.5ppm ±1digit |
Alarm Set Value | 1st stage: 10.0ppm 2nd stage: 15.0ppm |
Response Time*2 | 30s or less |
Display Mode | LCD (Manual backlight) |
Alarm Mode | Buzzer sounds, flashing red light, vibrator |
Approvals | Ex ib IIB T3 (TIIS) |
Functions | Remaining battery level, peak hold, memory of peak value, alarm functions except gas alarm (sensor malfunction, remaining battery level,air-adjustment malfunction) |
Operation Temperature | -10°C to +40 °C, 30 to 85 %RH (non-condensing) |
Operation Air Pressure | Air pressure ±10% |
Power Source | 1 x AAA alkaline dry cell |
Battery Life*3 | Up to 5000 hours (at 20°C with less than 5ppm) |
Dimensions | W65 x H64 x D22 mm (excluding protrusions) |
Weight | Approx. 75g (including battery) |
Standard Accessories | 1 x AAA alkaline dry cell, 1 x safety pin adaptor (with fixing screw) |
*1 Under identical measuring conditions.
*2 Operating at 20 ± 2°C.
*3 Battery life may vary with ambient conditions, conditions of use, storage period, battery manufactures, etc.
Approvals
Type Approved by TIIS Explosion-proof certification
Selectable Gases
hydrogen sulfide【H2S】
Portable Semiconductor Gas Detector
XPS-7II
Application
For gas leak inspection and concentration measurement at semiconductor factory where there is toxic gas
Features
- World’s Smallest Portable Gas Detector for NF3 Detection. NF3 can be detected without any optional equipment.
- The calibrated gas sensor unit can be replaced on site, reducing maintenance work.
- Large LCD
- 2-way power supply : Dry batteries and AC power supply (optional)
- Small and lightweight
- The speed of alarm sound changes depending on gas concentration.
Various semiconductor gases can be detected by changing the sensor unit.
Specifications
Detection Principle | Electrochemical, Electrochemical + pyrolyzer |
Target Gas | Semiconductor gases |
Sampling Method | Extractive |
Measuring Range | As per delivery specifications |
Accuracy *1 | ±10%F.S. except for XDS-7NF -30%F.S. to +10%F.S. for XDS-7NF |
Response time *1 | T60: Less than 60 seconds |
Display | Four-digit on LCD |
Power Source | Alkaline AA battery x 4pcs or Dedicated 100-240VAC/6VDC adapter (optional) *3 |
Continuous Operating Time*2 | More than 12 hours except for XDS-7NF More than 8 hours for XDS-7NF (by alkaline AA batteries (Toshiba LR6AN) at 20℃, with no gas alarm) |
Operating Temperature and Humidity | 0 to +40ºC, 30 to 85%RH |
Compliance | CE (EMC: 2014/30/EU) *3 *4 |
Dimensions | Approx. W62 × H150 × D128 mm (excluding protrusions) |
Mass | Approx. 1.3 kg |
*1. Under identical conditions.
*2. The operating time (battery life) may vary depending on environment and conditions of use, storage period, battery manufacturer etc.
*3. AC power adapter does not comply with CE marking.
*4. There are two types of EC-7 sensor stocker, global and domestic (for use in Japan). Global type is CE-marked.
Approvals
Type Approved by TIIS Explosion-proof certification
Selectable Gases
ammonia【NH3】,silane【SiH4】,dichlorosilane【SiH2Cl2】, arsine【AsH3】,phosphine【PH3】,diborane【B2H6】,hydrogen selenide【H2Se】,germane【GeH4】,chlorine【Cl2】,chlorine trifluoride【ClF3】,hydrogen chloride【HCI】,hydrofluoric fluoride【HF】,hydrogen bromide【HBr】,nitrogen monoxide【NO】,hydrogen sulfide【H2S】,carbon monoxide【CO】,disilane【Si2H6】,fluorine【F2】,ozone【O3】,nitrogen trifloride【NO3】
Portable Semiconductor Gas Detector
XPS-7
Application
For gas leak inspection and concentration measurement at semiconductor factory where there is toxic gas.
Features
- A single XPS-7 can be used for a variety of semiconductor gases, simply by changing the sensor unit.
- Cassette-type sensor units eliminate calibration.
Can be used for a variety of semiconductor gases by changing a plug and play gas sensor.
Specifications
Model | XPS-7 |
Detection Principle | Electrochemical cell |
Gas Detected | Semiconductor gases |
Sampling Method | Extractive |
Detection Range | Depends on the specifications |
Resolution | 1/100 of full scale |
Indication Accuracy | ±10% of full scale |
Alarm Mode | 2nd stage alarm type |
Alarm Indication | Intermittent buzzer, flashing lamp |
Response Time | 60s or less (60% response) |
Operating Temperature | 0 to 40°C |
Power Source | 4 x AA alkaline dry cells (*1) or an AC adaptor |
Battery Life*2 | Up to 12 hours (by alkaline dry cells at 20℃ without alarms) |
Dimensions | W62 x H150 x D128mm (excluding protrusions) |
Weight | Approx. 1.3kg |
Standard Accessories | Gas sampling hose with probe, shoulder strap, 4 x AA alkaline dry cells, Spare filters |
Optional Accessories | AC adaptor (100 VAC/6 VDC), sensor stocker, log data collection kit |
*1 Under identical measuring conditions.
*2 Battery life may vary with ambient conditions, conditions of use, storage period, battery manufactures, etc.
Approvals
Selectable Gases
arsine【AsH3】, ammonia【NH3】, carbon monoxide【CO】, nitric oxide【NO】, hydrogen chloride【HCI】, chlorine【Cl2】, ozone【O3】, chlorine trifluoride【ClF3】, dichlorosilane【SiH2Cl2】, disilane【Si2H6】, diborane【B2H6】, hydrogen bromide【HBr】, hydrogen selenide【H2Se】, sulfur dioxide【SO2】, nitrogen dioxide【NO2】, semiconductor manufacturing gases, hydrofluoric acid【HF】, fluorine【F2】, phosphine【PH3】, germane【GeH4】, silane【SiH4】, hydrogen sulfide【H2S】
MULTI GAS DETECTORS
Multi-gas detectors can detect multiple gases with a single detector. We offers a rich lineup that lets you select the combination of target gases to match your application.
Multi-Gas Detector
XA-4400II
Application
For safety check by wearing at construction site and steel plant, safety of site workers.
Features
- 40 hours or more of continuous operation with a single AAA Battery (when used in long-life mode)
- Compact and lightweight
70 (W) x 72 (H) x 20 (D) mm, approx. 130g - Sounding alarm, three flashing lights and vibrations
Alarm sound more than 95dB / 30cm - Ingress Protection is IP67
Water and dust proof. Can be used outdoors on a rainy day - Intrinsically Safe (Ex ia II CT 3)
Complies with hydrogen and acethylene explosion proof requirements - Sensor life of 2 years
Up to 4 gases of Oxygen/ Combustible gas/ Hydrogen sulfide/ Carbon monoxide can be measured at once with simultaneous display.
Specifications
Operating Temperature/Humidity | -20 to +50 °C, 30 to 85 %RH (non condensing) | |||
Continuous Use Time | Approx. 40 hours when the long-life mode is ON / Approx. 20 hours when the long-life mode is OFF Approx. 1200 hours without combustible gas sensor (at 25 degrees C, without alarm,backlight OFF) | |||
Power Source | 1 x AAA Panasonic alkaline battery | |||
Display | LCD | |||
Gas Alarm | Buzzer sound, Flashing RED lamp, Vibration, LCD (automatic recovery) | |||
Intrinsically safe | Ex ibd IIC T3 (TIIS) II 1 G Ex ia IIC T3 Ga (ATEX) Class I, Zone 0, AEx ia IIC T3 Hazardous Locations. (UL) *pending | |||
Ingress Protection | IP67 | |||
Function | Self-diagnosis (sensor trouble), Automatic air adjustment, Remaining battery level, Peak-hold, LCD backlight, Buzzer stop for gas alarm, Time & Temperature indication, Alarm test, Buzzer volume, Silent mode, Long-life mode, Data logging (datalogger kitis necessary for logging) | |||
Dimensions | W70 x H72 x D26 mm (excluding protrusions) | |||
Weight | Approx. 130g (excluding battery) | |||
Accessories | Safety-Pin band, alkaline battery, 2 x filter element for replacement | |||
Options | Datalogger kit, soft case, belt clip |
Approvals
*pending
Type Approved by TIIS Explosion-proof certification
Selectable Gases
oxygen【O2】, carbon monoxide【CO】, hydrogen sulfide【H2S】, methane【CH4】 or isobutane【i-C4H10
Personal CO/O2 Monitor
XOC-2200
Application
- For safety check by wearing at construction site and steel mills, safety of site workers.
Features
- Can be used continuously for 5000 hours.
- 3 types of Alarm: loud buzzer, alarm lamp and vibration.
- Available with TWA (Time Weighted Average) concentration display, peak memory, and peak hold function.
Pocket-sized personal oxygen and carbon monoxide detector.
Specifications
Response Time*2 | 20s or less | 30s or less |
Display Mode | LCD (Manual backlight) | |
Alarm Mode | Buzzer sounds, flashing red light, vibrator | |
Approvals | Ex ib IIB T3 (TIIS) | |
Function | Remaining battery level, peak hold, peak value memory, readout of time
weighted average, remainig battery level, alarm functions except gas alarm (time weighted average, sensor malfunction, battery level, zero-adjustment malfunction), gas calibration, gas concentration indication | |
Operation Temperature | -10°C to +40°C, 30 to 90 %RH (non-condensing) | |
Operation Air Pressure | Air pressure ±10% | |
Power Source | 1 x AAA alkaline dry cell | |
Battery Life*3 | Up to 5,000 hours (at 20°C with less than 20ppm of CO and more than
20.3vol% of O2) | |
Dimensions | W65 x H64 x D22mm (excluding protrusions) | |
Weight | Approx. 75g (including batteries) | |
Standard Accessories | 1 x AAA alkaline dry cell, 1 x safety pin adaptor (with fixing screw) |
*1 Under identical measuring conditions.
*2 Operating at 20 ±2°C.
*3 Battery life may vary with ambient conditions, conditions of use, storage period, battery manufactures, etc.
Approvals
Type Approved by TIIS Explosion-proof certification
Selectable Gases
oxygen【O2】, Carbon monoxide【CO】
Personal H2S/O2 Monitor
XOS-2200
Application
- For safety check before working in underground construction site in the tank, manhole and tunnel etc.
- For safety of site workers.
Features
- Can be used continuously for 5000 hours.
- 3 types of Alarm: loud buzzer, alarm lamp and vibration.
- Thin, lightweight design.
Pocket-sized personal oxygen and hydrogen sulfide detector.
Specifications
Model | XOS-2200 | |
Gas Detected | Oxygen (O2) | Hydrogen Sulfide (H2S) |
Detection Principle | Galvanic cell | Electrochemical cell |
Sampling Method | Diffusion | |
Detection Range (Service Range) | 0 to 25 vol% (25 to 50 vol%) | 0 to 30.0 ppm (30.1 to 100 ppm) |
Resolution | 0.1vol% | 0-35.0 ppm: 0.1ppm 35-100ppm: 5ppm |
Indication Accuracy*1 | Within ±0.5vol% ±1 digit | Within ±1.5ppm ±1 digit |
Alarm Set Value | 1st stage: 19.5vol% 2nd stage: 18.0vol% | 1st stage: 10.0ppm 2nd stage: 15.0ppm |
Response Time*2 | 20s or less | 30s or less |
Display Mode | LCD (Manual backlight) | |
Alarm Mode | Buzzer sounds, flashing red light, vibrator | |
Approvals | Ex ib IIB T3 (TIIS) | |
Function | Remaining battery level, peak hold, memory of peak value, alarm functions except gas alarm (sensor malfunction, remaining battery level, air-adjustment malfunction), gas concentration indication | |
Operation Temperature | -10 to +40 °C, 30 to 85 %RH (non-condensing) | |
Operation Air Pressure | Air pressure ±10% | |
Power Source | 1 x AAA alkaline dry cell (LR03) | |
Battery Life*3 | Up to 5,000 hours (at 20°C without alarm) | |
Dimensions | W65 x H64 x D22 mm (excluding protrusions) | |
Weight | Approx. 75g (including batteries) | |
Standard Accessories | 1 x AAA alkaline dry cell, 1 x safety pin adaptor (with fixing screw) |
*1 Under identical measuring conditions.
*2 Assuming 90% response and operating at 20 ±2°C.
*3 Battery life may vary with ambient conditions, conditions of use, storage period, battery manufactures, etc.
Approvals
Type Approved by TIIS Explosion-proof certification
Selectable Gases
oxygen【O2】, hydrogen sulfide【H2S】
Multi Gas Detector
XP-302M
Application
- Daily inspections in various plants, safety of site workers.
- For safety check before working in underground construction site in the tank, manhole and tunnel etc. and safety of site workers.
Features
- Compact and Lightweight.
- Large, blight display with automated backlight.
- Monitors LEL, O2, CO and H2S
Oxygen/ Combustible gas/ Hydrogen sulfide/ Carbon monoxide can be measured at once with simultaneous display.
Specifications
Operating Temperature & Humidity | -10 to +40 °C, 95%RH (non condensing) | ||||
Power Source | 4 x AA alkaline dry cells | ||||
Display | A large LCD with backlight provides simultaneous and continuous readout of all gases being monitored. 3 user-selectable display modes (standard display / graphic display/English display). | ||||
Alarms | 90+ dB buzzer, flashing LCD and warning lamp | ||||
Battery Life*3 | 8+ hours on 4 x AA alkaline cells (20°C, no alarm, no backlight and
datalogging OFF) | ||||
Safety Design | Intrinsically safe design Exibd II BT3 | ||||
Function | ・Automatic backlight (in dim light or alarm condition) ・Zero adjustment
・Peak hold ・Buzzer control・Low flow alarm ・Datalogging function (up to 150 hours) ・Buzzer stop・Alarm test ・Display of remaining battery level, current time and temperature | ||||
Dimensions | W152 x H152 x D42 mm (excluding protrusions) | ||||
Weight | Approx. 870g |
- Under identical conditions
- T90
- It depends on the environmental conditions, service conditions, storage period, and battery manufacturers
- Non explosion-proof type
- Please contact our dealers / distributors for available accessories
Selectable Gases
oxygen【O2】, carbon monoxide【CO】, hydrogen sulfide【H2S】, methane【CH4】 or isobutane【i-C4H10】
INCOMPLETE COMBUSTION GAS DETECTORS (CO METER)
Combustion emission gas detectors are used for maintenance and inspections of combustion equipment and to measure combustion efficiency. These detectors pursue operability, are equipped with a wealth of functions, and achieve superior ease-of-use.
Carbon Monoxide Detector
XP-333IIA
Application
For measurement of carbon monoxide concentration in the combustion exhaust gas due to incomplete combustion of gas equipment.
Features
- Detection range is 0 to 0.499vol% for CO
- Compact and light weight
- Detect at 3 patterns: Actual, Mean and Peak value
- High sensitivity and selectivity sensor for CO3 different audible and visual alrm levels
- 3 x AA alkaline batteries
- Auto-Zero Adjustment
- Including soft case
Suitable for maintenance of gas-fired boiler, gas water heater, etc.
Specifications
Model | XP-333IIA | ||
Detection Principle | Electrochemical cell | ||
Sampling Method | Extractive | ||
Measuring Range | 0 to 0.499 vol% | ||
Response Time | <14 sec. (T90 excluding sampling hose) | ||
Operating Temperature | -10 to +40 °C | ||
Power Source | 3 x AA alkaline batteries | ||
Battery Life Time | Approx. 100 hrs. | ||
Dimensions | W60 x H155 x D40 mm | ||
Weight | Approx. 270g (excluding batteries) |
Selectable Gases
carbon monoxide【CO】
OTHERS
Real-time VOC monitor
XP-3120-V
Application
- Oil & Gas
- Industrial Safety
- Environmental Measurement
- Indoor Air Quality
Features
- Compact and light-weight
- Easy to use
- Intrinsically safe: Ex ib d IIB T3 (TIIS)
- Stable measurement with long-term proven sensor
- Able to monitor concentration changes with data-logging function
- Low initial cost
Portable VOC monitor suitable for on-site measurement of comprehensive VOCs.
Specifications
Model | XP-3120-V |
Gas Detected | VOC (Calibration Gas: Toluene) |
Sampling Method | Extractive |
Detection Principle | Hot-wire semiconductor |
Detection Range | Low range: 0 to 100 ppm High range: 0 to 1000 ppm |
Indication Accuracy | ± 10% of full scale |
Display | Main LCD: Digital-LCD with backlight Sub LCD: Clock display |
Alarm | Non-alarm |
Explosion-proof Structure | Ex ib d IIB T3 (TIIS) |
Operation Temperature | 0 to +40 °C |
Power Source | 4 x AA alkaline dry battery |
Continuous Operation | With alkaline battery: approx 25 hours (at 20°C, backlight OFF) |
Dimensions | W82 x H162 x D36 mm |
Weight | Approx. 450g (excluding batteries) |
Standard Accessories | Soft case, 4 x AA alkaline dry battery, Gas sampling hose (1m, for solvent model SH-401), Replacement filter, Probe with filter/moisture trap |
Optional Items | Datalogger kit (CD-ROM + USB cable), AC adaptor, Activated carbon filter set |
Approvals
Type Approved by TIIS Explosion-proof certification
Type Approved by TIIS Explosion-proof certification
HCFC Detector
XP-704III
Application
For maintenance work of air conditioning.
Features
- Most of refrigerant gases can be detected
- Automatic stop pump function
- Automatic gas exhaust mode
- Equivalent to IP22 (in soft case)
A small leak of HCFC/HFC gas can be detected.
Specifications
Model | XP-704III |
Gas Detected | R-22, R-32, R-404A, R-407C, R600a, R410A, R-134a, R-290,
HFO-1234yf |
Detection Principle | Hot-wire semiconductor sensor |
Sampling Method | Extractive |
Detectable Leak Rate (annual) | R-22: 2.84(g), R-32: 1.71(g), R-404A: 3.30(g), R-407C: 3.12(g),
R600a: 1.91(g), R410A: 2.82(g), R-134a: 20.09(g), R-290: 1.45(g), HFO-1234yf: 3.74(g) |
Detectable Gas Concentration | 5 ppm (R-134a: 30ppm) |
Response Time | Within 10 seconds |
Power Supply | Size AA alkaline batteries x 2 |
Battery Life*1 | Approx. 12 hours (with size AA alkaline batteries) |
Degree of Protection | Equivalent to IP22 |
Operating Pressure | Atmospheric pressure (800 to 1100 hPa) |
Operating Temperature and Humidity | 0 to +40 °C Less than 85%RH (with no condensation) |
Dimensions | W38 x H130 x D32 mm (excluding protrusions) |
Weight | Approx. 190g (including batteries and soft case) |
Accessories | Soft case, Drain Filter, Replacement Filter, Gas Probe, Dust Filter, Hand Strap, Size AA Alkaline Battery x 2, etc. |
*1 It may vary based on the environmental conditions, operating conditions, strage time, battery manufacturer, etc.
Approvals
Selectable Gases
R-22【CHClF2】, R-23【CHF3】, R-32【CH2F2】, R407C, R410A, R404A, R600a, R134a, R1234yf, combustible gas
Portable VOC Analyzer
XG-100V
Application
- Measurement for VOC in indoor
- VOC inspection of electrical appliances
Features
- High sensitivity
Low concentrations of the target gas can be analyzed and measured with high accuracy. - Field measurement
Easily transportable to use on site. - No need of carrier gas.
- Simple operation
Simply inject the target gas into a gas inlet with a syringe or Auto Sampler Option.
Pocket-sized personal oxygen and hydrogen sulfide detector.
Specifications
Model | XG-100V |
Substance Measured | Toluene, xylene, ethyl benzene and styrene |
Measurement Range (measuring toluene) | Minimum detection limit: 4mg/m3, 1ppb Maximum detection limit: 3700mg/m3, 1000ppb |
Repeatability | Within ±5% (RSD) (Toluene 70ppb) |
Carrier Gas | Atmospheric air |
Sample Injection Method | Direct injection by syringe (sample volume: 10ml) |
Operating Temperature | 5 to 35 °C |
Power Source | 100 VAC, 50/60 Hz |
Dimensions | W240 x H190 x D380 mm |
Weight | Approx. 10kg |
Standard Accessories | Data analysis software (hardware requirement: Windows XP), calibration
gas, 3 x syringes for sample injection, AC power cable, RS232C cable, USB-RS232C conversion cable, 8 x C alkaline dry cells. |
Selectable Gases
toluene【C6H5CH3】, xylene【C6H4(CH3)2】, ethyl benzene【C6H5C2H5】, styrene【C6H5CH=CH2】
Grease Steel Dust Meter
SDM-72
Video
Application
- Simple diagnosis and trend monitoring of the wear condition of greased bearings, gears, etc.
- Pre-diagnosis for Ferrography method and SOAP method
Features
- Able to diagnose the bearing condition, even long before wear-induced vibration becomes detectable, by measuring the amount of steel dust in the grease around the bearing.
- Simple operation – simply measured by a grease sample
Oxygen/ Combustible gas/ Hydrogen sulfide/ Carbon monoxide can be measured at once with simultaneous display.
Specifications
Model | SDM-72 |
Measurement Principle | Magnetic balance type electromagnetic method |
Substance Measured | Steel dust concentration in grease |
Measurement Range | 0 to 5.000 %Wt |
Minimum Resolusion | 0.001 %Wt |
Zero adjustment | Automatic adjustment |
Amount of sample | Approx. 0.8ml |
Power Source | 4 x AA (R6) alkaline drycells |
Battery Life*1 | Up to 30 hours by alkaline cells |
Operating temperature | 0 to +40 °C |
Dimensions | W84 x H190 x D40 mm |
Weight | Approx. 500g (including batteries) |
Standard Accessories | Carrying case, grease sampling spatula, grease sample case (10 pieces) and 4 x AA (R6) alkaline drycells |
*1 Battery life may vary with ambient conditions, conditions of use, storage period, battery manufacturers, etc.
Oil Steel Dust Checker
SDM-73
Video
Application
- Simple diagnosis of the wear condition of bearings, gears, cylinders, etc. in rotational equipment
- Monitoring steel dust contamination in hydraulic oil and grinding oil
Features
- Able to diagnose the bearing condition, even long before wear-induced vibration becomes detectable, by measuring the amount of steel dust in the oil around the bearing.
- Simple operation – simply measured by an oil sample
Able to diagnose the bearing condition, even long before wear-induced vibration becomes detectable, by measuring the amount of steel dust in the oil around the bearing.
Specifications
Model | SDM-73 |
Measurement Principle | Magnetic balance type electromagnetic industion method |
Substance Measured | Steel dust concentration in lubricating oil |
Measurement Range | 0 to 19999wt ppm |
Minimum Resolusion | 1wt ppm |
Zero adjustment | Automatic adjustment |
Amount of sample | 1.5ml |
Power Source | 4 x AA (R6) alkaline drycells |
Battery Life*1 | Up to 30 hours by alkaline cells |
Operating temperature | 0 to 40 °C |
Dimensions | W84 x H190 x D40 mm |
Weight | Approx. 500g (including batteries) |
Standard Accessories | Carrying case, 2ml syringe (5 pieces), oil sampling nozzle (2 pieces),
syringe holder and 4 x AA (R6) alkaline drycells |
- Battery life may vary with ambient conditions, conditions of use, storage period, battery manufacturers, etc.