Indicator Unit
V3-Series
Features
- Easy to notice the alarm status with 3 color LED display
- Maintenance mode which will stop the alarm output to external system devices during the maintenance to allow a maintenance work alone
- it can be raplace in the existing COSMOS gas detection system due to the failures.
- The cover attachment of PCB makes safe to use
- The switch cover prevents accidental operation.
- the switch cover for alarm unit can also be selected (Option).
Specifications
Model | V3 | ||
Type | Hv, Hi, Cv, Ci, Tv, Ti, D, O | M | |
Gas Concentration Display | 3-color LED bar graph (50 split) | ||
Alarm Indication |
Power Lamp | Normal: Green POWER lamp lights up, Initial energization: Green POWER lamp flashes for 30s. | |
Alarm Lamp | Red ALARM lamp flashes (lights up on reset) | ||
Trouble Lamp | Yellow TROUBLE lamp flashes | ||
Alam Set Value | Adjustable within the detecion range for 1st and 2nd stage alarm | ||
Alarm Accuracy | Combustible gas: Within ±25% of alarm set value | Depends on the detector head specifications |
|
Toxic gas: Within ±30% of alarm set value | |||
Oxygen: Within ±1.0vol% of alarm set value | |||
Response Time | Combustible gas: Within 30s at 160% concentration of alarm set value | Depends on the detector head specifications |
|
Toxic gas: Within 60s at 160& concentration of alarm set value | |||
Oxygen: Within 5s at 10vol% (oxygen deficiency) | |||
External Output | Contact Output | 1c no-voltage (100 VAC/1 A resistance load, 24 VDC, 1 A-resistance load), 1a for trouble contact | |
Analog Output | 4-20mADC | ||
Power Source | 24 VDC ±10% | ||
Power Consumption | Approx. 5.0W (excluding power consumption of extractive gas detector) | Approx. 5.0W (excluding power consumption of detector) |
|
Other Functions | Linearization, maintenance mode, zero suppression (Option) Peak hold function, alarm delay, low flow arte alarm function (can be set by connecting detector) |
||
Operating Temperature/Humidity* | -10 to +40 °C 10 to 90 %RH |
||
Dimensions | W36 x H144 x D70 mm | ||
Weight | Approx. 600g (including 450g single case) |
Connectable Gas Detectors
Indicator Unit Models * is conventionalmodels (v, v2 series) |
Connectable Detectors | Gas Detected | ||
Diffusion | Extractive | |||
Combustible
Gas (For ppm) |
type Hv *V2H |
KD-5A /KD-5B | PD-5N/PD-5F/PD-4HP |
Combustible Gases (CH4/ LPG etc.) |
type Hi *VH |
KD-2A/KD-3A/KD-14 | PE-2CC/PE-2DC | ||
Combustible
Gas (For LEL) |
type Cv *V2C |
KD-5A/KD-5B | PD-5N/PD-5F | Combustible Gases (CH4/ LPG etc.) |
type Ci *VC |
KD-2A/KD-3A | PE-2CC/PE-2DC | ||
For NH3 | *VZN | KD-2AS | PE-2CZ | NH3 |
Inert gas
/For vol% |
type Tv *V2T |
KD-5A/KD-5B | PD-5N/PD-5F | H2/Helium/Argon
/CO2/CH4 |
type Ti *VT |
KD-2A/KD-3A | PE-2CC/PE-2DC | ||
Toxic gas | type D *VD *V2D |
KCM-3A/KD-5D | PS-2CD/PS-2DE
/PS-2CKIII/PS-2DKP /PS-2DPS/PS-4DP |
Semiconductor manufacturing gases
/Toxic gas |
Oxygen | type O *VO *V2O |
KD-5O/KS-2O | PS-2OP/PS-2OE
/PS-4OP |
Oxygen |
For analog
output |