Digital Oxygen Indicator
XO-326IIs
Application
- For Safety check and safety in plants, tank, manhole, and tunnel construction
- For safety of site workers
Features
- Continously for up to 15,000 hours with 2 x AA alkaline batteries
- Automatic air adjustment
- Plug-in sensor installed
Specifications
Model | XO-326IIsA XO-326IIsA-V |
XO-326IIsB XO-326IIsB-V |
XO-326IIsC XO-326IIsC-V |
Cable Length | 5m | 1m (spiral cable) | 10m |
Gas Detected | Oxygen | ||
Detection Principle | Galvanic cell | ||
Sampling Method | Diffusion Type | ||
Detection Range
(Service Range) |
0 to 25.0 vol%
(25.1 to 40.0 vol%) |
||
Indication Accuracy | Within ±0.5vol% | ||
Display Resolution | 0.1vol% | ||
Alarm Set Value | 1st stage: 19.5vol% 2nd stage: 18.0vol% |
||
Response Time | Within 20 seconds | ||
Alarm Function | Buzzer sounds, Red lamp blicks, LCD display blincks (latching), Vibration (for vibration specifications |
||
Power Source | 2 x size AA alkaline battery (LR6/ made by PANASONIC) | ||
Continuous Use | Approx. 15,000 hours | ||
Explosion-Proof Structure |
Ex ia II CT3 X (Japan) | ||
Protection Class | IP20 or equivalent | ||
Operation Temperature/Humidity | -10 to +40 °C
30 to 85 %RH (non condensing) |
||
Dimensions (excluding protrusions) |
W66 x H170 x D29 mm | W66 x H120 x D29 mm | W66 x H200 x D29 mm |
Weight | Approx. 340g | Approx. 265g | Approx. 410g |
Approvals
Type Approved by TIIS Explosion-proof certification
Conforms to JIS T 8201
Selectable Gases
Oxygen【O2】